COMPLETE FILTRATION SOLUTIONS

FOR YOUR CRITICAL PROCESSES

You are here: Home » Products » Filter Housings » Magnetic Separator for Liquid Cooling
Magnetic Separator for Liquid Cooling
Magnetic Separator for Liquid Cooling Magnetic Separator for Liquid Cooling

loading

Magnetic Separator for Liquid Cooling

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
sharethis sharing button
  • LM

  • Others

  • Filter Housings

  • Metal

Availability:
Quantity:

Magnetic Separator for Liquid Cooling – High‑Intensity Magnetic Rods Remove

The Magnetic Separator is incorporates high‑strength magnetic rods (14,000 Gauss, 3/5/7 units optional) to effectively capture ferrous particles, weld slag, and metal ions generated during operation.


APPLICATIONS

  • Primary Loop of Liquid Cooling: Installed between the heat rejection unit (dry cooler/cooling tower) and the CDU to capture iron chips and weld slag from external piping or heat exchangers.

  • Secondary Loop of Liquid Cooling: Placed between the CDU outlet and servers/cold plates to protect micro‑channel cold plates and quick‑disconnects from ferrous particle abrasion.


FEATURES

BENEFITS OF MAGNETIC SEPARATOR FOR LIQUID COOLING
  • Strong Magnetic Capture: Utilizes 14,000 Gauss rare‑earth magnetic rods to efficiently remove ferrous particles, weld slag, and metal ions from coolant, preventing system wear and clogging.

  • Scalable Flow Capacity: Available with 3, 5, or 7 magnetic rods to accommodate different flow rates in liquid cooling loops, with custom options.

  • Ultra‑Clean Surface Finish: 304 stainless steel housing with mirror polishing and passivation – no dead legs, no particle shedding, fully compatible with DI water, PG25, and other coolants.

  • Maintenance‑Free Long Life: No moving parts; only occasional rod extraction for cleaning – simple operation, reducing labor and spare parts costs.


ORDERING INFORMATION

MATERIAL LINING NO. of FILTERS CONNECTION LENGTH(IN) SEAL INLET/OUTLET
304 Without 1 222 10'' Silicone Tri-Clamp DN25
316 PTFE 3 226 20'' EPDM Tri-Clamp DN40
WCB(Mild Steel) FPA 4 M20 30'' Viton Tri-Clamp DN50
PPH(Homopolymer PP) Fluorine 7 3M 40'' TEV Flange DN25

Butyronitrile 25 PARKER
Butyronitrile Flange DN40

PE 150 PALL
PTFE Flange DN50



PHOSPHOR

Flange DN80



38-5

Flange DN150






DIN Flange DN40


Q1: What is the primary function of the Magnetic Separator in liquid cooling loops?

A1: It incorporates high-strength magnetic rods to efficiently capture ferrous particles (iron chips), weld slag, and suspended metal ions generated during system operation, preventing downstream component wear and clogging.


Q2: What is the magnetic strength of the rods used in this equipment?

A2: The separator utilizes ultra-high-intensity 14,000 Gauss rare-earth magnetic rods to ensure strong magnetic capture of even micro-fine magnetic debris.


Q3: How does the configuration adapt to different fluid flow rates in liquid cooling systems?

A3: It offers scalable flow capacity with options for 3, 5, or 7 magnetic rods to accommodate different flow rates in the cooling loops, and custom specifications are also available.


Q4: Where should the Magnetic Separator be installed within the Primary Loop of a liquid cooling system?

A4: In the primary loop, it is typically installed between the heat rejection unit (such as a dry cooler or cooling tower) and the Cooling Distribution Unit (CDU) to intercept iron chips and weld slag coming from external piping or heat exchangers.


Q5: What protective benefit does this separator provide when deployed in the Secondary Loop?

A5: Placed between the CDU outlet and the servers/cold plates, it acts as a critical shield to protect micro-channel cold plates and quick-disconnect fittings from devastating ferrous particle abrasion.


Q6: What surface treatments are applied to the housing to meet ultra-clean plumbing requirements?

A6: The housing is constructed from 304 stainless steel and undergoes mirror polishing and passivation. This delivers a dead-leg free, non-particulate releasing surface that maintains fluid pathway purity.


Q7: Is this magnetic filter compatible with specialized chemical coolants?

A7: Yes, the system's ultra-clean and passivated surface finish ensures full compatibility with deionized water (DI water), PG25 (propylene glycol blend), and other mainstream cooling fluids.


Q8: What makes this device low-maintenance and cost-effective over its service life?

A8: The separator has no moving parts and requires no consumable elements; maintenance only requires occasional extraction of the magnetic rods for manual cleaning, which drastically reduces labor and spare parts costs.


Q9: What types of high-performance o-ring/seal materials are supported in the Ordering Information guide?

A9: Depending on your temperature and chemical resistance requirements, the guide supports premium options including Silicone, EPDM, Viton, and TEV (PTFE encapsulated rubber).


Q10: What piping connection (Connection) configurations are available for order?

A10: LOONG Filtration offers versatile connection methods, including sanitary Tri-Clamp options (e.g., DN25/DN40/DN50) and robust industrial Flange specifications (ranging from DN25 up to DN150, including DIN Flange DN40).

CONNECT NOW FOR A QUICK REPLY

Have a quiry? Contact us now and we'll get back to you promptly.
INQUIRY
A SPECIALIST IN FILTRATION EXCELLENCE!
CONTACT US
 Tel: +86-571-26232618
 WhatsApp: +8619558243921
 Email:
sales@loongfiltration.com
Address: 19.Building 12, No. 42, Tianhe Road, Donghu Street, Linping, Hangzhou, Zhejiang,P.R. China

COMPANY

PRODUCT

APPLICATION

JOIN AGENT 
Copyright 2025 LOONG FILTRATION All Rights Reserved. SitemapPrivacy Policy