FCN/FPN/FEN/LCN
Pharma&Biotech, Microelectronics, Fine Chemical
Membrane Filter Cartridges
Nylon
| Availability: | |
|---|---|
| Quantity: | |
High Flow, Low Binding, Cost-Effective
The sterilizing-grade Nylon Membrane Filter Cartridge offers an economical,
high-performance solution for critical filtration. Its naturally hydrophilic
membrane requires no pre-wetting, enabling immediate high flow rates
and throughput with low protein binding for maximum product recovery.
With broad chemical compatibility—especially with alcohols and solvents—and
reliable bacterial retention, it is widely used in pharmaceutical, biotech,
microelectronics, and food and beverage applications.
• Organic Solvent Filtration with Broad Compatibility
• Final Filtration for High-Purity Water Systems
• Photoresist & Developer Filtration
• Pre-filtration of Chemical Intermediates
• Purification for Solvent Recovery Systems
• Sterile Filtration for LVPs & SVPs
• Precision Filtration for Purified Water & WFI
• Filtration of Veterinary Drug Products
• Clarification & Sterilization of Biologicals & Vaccines
• Sterile Filtration of Cell Culture Media & Buffers
• Filtration of API Solutions
• Pharmaceutical Process Solvent Filtration
• Final Filtration for DI Water Systems
• Positive Photoresist Filtration
• Polar Solvent Filtration for IPA and Acetone
• Final Filtration for UPW Rinse Water
• Pre-filtration for CMP Slurries
The LC-Series Nylon pleated micro-porous filter cartridge features high strength, stable filtration rating, and excellent water-based compatibility. It is particularly suitable for circulation protection in MLCP micro-channel liquid cooling systems and the pre-filtration stage in fluorinated fluid immersion liquid cooling. Its high flow rate, low pressure drop, and large dirt-holding capacity design can effectively intercept particulates during system operation, ensuring the long-term stable operation of cold plates and liquid cooling equipment. It is an ideal filtration component for data center liquid cooling systems.
•High mechanical strength and excellent pressure resistance, particularly suitable for liquid cooling systems with high circulation pressure;
•Uniform pore size and stable filtration rating, featuring good particle retention capability;
•Good hydrolysis resistance, excellent compatibility with water-based coolants (DI water, ethylene glycol);
•High flow rate and low pressure drop design, extending service life;
•Good temperature resistance, maintaining structural stability under prolonged high flow rate impact;
•Customizable interface sizes and forms for volume customers.
Pore Size (µm): 0.1 • 0.22 • 0.45• 1.0• 3.0• 5.0
Ready-to-Use Hydrophilicity
No alcohol pre-wetting required
Broad Chemical Compatibility
Excellent resistance to alcohols and most solvents
Low Extractables & Protein Binding
Ideal for sensitive biological applications
High Flow Rates
Optimized membrane structure for efficient processing
MEMBRANE |
Nylon Nylon66(For FPN Series) |
CAGE & SUPPORT & END CAPS |
PP |
O-RINGS/GASKET |
Silicone/Viton/EPDM/TEV |
PP |
<60 ℃ |
PP WITH STAINLESS STEEL LINED END CAP |
<85 ℃ |
PP WITH STAINLESS STEEL LINING |
<95 ℃ |
POSITIVE/REVERSE PRESSURE RESISTANCE |
4 bar/2 bar (23 ℃) |
PH RANGE |
6-12(for FPN Series) |
OUTER DIAMETER |
68 mm |
LENGTH |
10", 20", 30", 40" |
ENDOTOXIN |
<0.25 EU/ml |
EXTRACTABLE |
≤50 mg/10" |
0.22 μm |
≥2.8 bar |
SERIES |
MATERIAL |
RATING(μm) |
END CAP |
LENGTH(in) |
SUPPORT |
SEAL |
PORT |
Electronics |
Nylon |
0.1μm |
222/Fin |
2.5'' |
PP |
Silicone |
Interface lining steel |
Phamarmical |
0.22μm |
222/Flat |
5'' |
PBT |
EPDM |
Fully lining |
|
Chemical |
0.01μm |
226/Fin |
10'' |
PVDF |
Viton |
Skeleton lining |
|
1.0μm |
226/Flat |
20'' |
PFA |
TEV |
|||
3.0μm |
DOE/Flat |
30'' |
PE |
Butyronitrile |
|||
10μm |
215/Fin |
40'' |
GF |
PTFE |
|||
0.22+0.22μm |
215/Flat |
PTFE gasket (soft) |
|||||
M20 |
Metal-graphite Wound |
||||||
M30 |
|||||||
216/Fin |
|||||||
216/Flat |
|||||||
M15 |
|||||||
Insertion Type |
|||||||
Barbed Type |
What is a nylon membrane filter cartridge mainly used for?
A nylon membrane filter cartridge is mainly used for fine filtration and sterilizing-grade filtration of aqueous solutions, alcohol-containing liquids, solvents, pharmaceutical process fluids, and high-purity chemical streams. Its naturally hydrophilic membrane provides fast wetting and high flow, making it suitable for pharmaceutical, biotech, microelectronics, fine chemical, and liquid-cooling applications.
Why is a nylon membrane suitable for solvent and alcohol filtration?
Nylon offers good compatibility with many organic solvents and alcohol-based liquids while maintaining strong mechanical performance. Its hydrophilic nature also allows immediate wetting without alcohol pre-wetting in many aqueous applications. Final compatibility should still be confirmed according to the specific solvent, concentration, temperature, contact time, cartridge construction, and seal material.
How do I choose the right micron rating for a nylon filter cartridge?
The correct micron rating depends on the filtration objective, required particle or microbial retention, contamination level, flow rate, and downstream process requirements. Fine grades such as 0.22 μm are typically selected for higher retention applications, while larger pore sizes may be used for clarification or prefiltration. Selection should consider both retention performance and allowable pressure drop.
Is a nylon filter cartridge suitable for protein-containing or biological solutions?
Nylon can be used for certain biological and pharmaceutical fluids, but protein binding should be considered when product recovery is critical. For protein-sensitive applications, compatibility with the specific molecule, buffer composition, contact time, and process conditions should be evaluated before use. Where low protein adsorption is a priority, membrane selection should be based on the actual process requirements.
What are the operating limits of the nylon membrane filter cartridge?
Operating limits depend on the cartridge construction. The listed standard PP configuration is suitable below 60°C, while versions with stainless steel lined end caps or stainless steel lining can support higher temperatures. The listed positive/reverse pressure resistance is 4 bar / 2 bar at 23°C, and the FPN Series has a listed pH range of 6–12.
When should a nylon membrane filter cartridge be replaced?
Replacement should be based on validated process limits rather than a fixed operating time. Typical indicators include increasing differential pressure, reduced flow rate, longer filtration time, or failure to meet required retention or product-quality specifications. Actual service life depends on contaminant loading, pore size, fluid properties, chemical exposure, temperature, and operating conditions.