SFM
Pharma&Biotech, Microelectronics, Laboratory
Disc Filters
Nylon, PTFE, PP, Mixed cellulose (MCE), Glass fiber (GF), PVDF
| Availability: | |
|---|---|
| Quantity: | |
Compact Disc Filter Cartridge for
Laboratory & Small Batch Processes
This series of Compact Disc Filter Cartridge is designed for laboratory and
small-scale production use. Manufactured with heat-sealing technology to
eliminate adhesive contamination, they provide secure sealing with ultra-low
extractables. Their robust yet compact construction withstands high-temperature
sterilization, while the disposable design ensures operational safety. Ideal for
protecting sensitive equipment from particulate and microbial contamination
in applications such as cell culture, bioreactors, and vacuum systems.
Provides reliable intake air filtration for sensitive electronic equipment and analytical instruments
Suitable for various gas and liquid filtration needs in R&D and small-scale production
Removes microorganisms and particles from gas streams to maintain optimal bioreactor conditions
Provides balanced, clean gas environment for cell growth and metabolism processes
Effectively protects vacuum pumps and related equipment from particulate and liquid intrusion
Clean Sealing Technology
Heat-sealing process completely eliminates adhesives, ensuring media purity and reliable sealing performance
Compact & Efficient Design
Small footprint with excellent filtration performance, ideal for space-constrained applications
Outstanding Thermal Stability
Excellent heat resistance supports repeated sterilization cycles, meeting strict sterile requirements
User-Friendly Operation
Disposable design simplifies replacement procedures, reduces handling time and prevents cross-contamination
Housing | PP |
Filter Material | PP/MCE/Nylon/PES/PTFE/Hydrophilic PTFE/ PVDF/Hydrophilic PVDF/Glass Fibe |
Max. Temperature | ≤60 ℃ |
Maximum Operating Pressure | 3.5 bar@23 ℃; 3.0 bar@60 ℃(Liquid) 3.0 bar@23 ℃; 2.5 bar@60 ℃(air) |
Removal Ratings (mm) | 0.1/0.22/0.45/0.65/1.0/3.0/10/0.22+0.22、0.22+0.45μm |
Endotoxi | <0.25 EU/ml |
Extractabl | ≤15 mg/5" |
DIAMETE | φ52 (Suitable for 5-8mm tube) |
MEDIA DIAMETER | 40mm |
Filtration Area | 20 cm² |
Inlet | 1/4"-1/2" Pagoda joint |
Outle | 1/4"-1/2" Pagoda joint |
SERIES | MATERIAL | RATING(μm) |
Phamarmical | PP | 0.1μm |
Laboratory | MCE | 0.22μm |
Electronics | Nylon | 0.45μm |
PES | 0.65μm | |
PTFE | 1.0μm | |
Hydrophilic PTFE | 3.0μm | |
PVDF | 10μm | |
Hydrophilic PVDF | 0.22+0.22μm | |
GF | 0.22+0.45μm |
What is the Compact Disc Filter Cartridge mainly used for?
The Compact Disc Filter Cartridge is designed for laboratory, R&D, and small-batch filtration where compact size, low hold-up volume, and reliable particle or microbial retention are important. Typical applications include precision instrument protection, bioreactor inlet filtration, cell culture gas treatment, vacuum system protection, and other small-scale liquid or gas filtration processes.
What filter media are available for the Compact Disc Filter Cartridge?
Available media include PP, MCE, Nylon, PES, PTFE, hydrophilic PTFE, PVDF, hydrophilic PVDF, and glass fiber. The appropriate material depends on the process fluid or gas, required filtration rating, chemical compatibility, protein-binding requirements, wettability, and whether the application involves liquid or gas filtration.
How do I choose the right micron rating for this disc filter?
The correct rating depends on the filtration objective, particle or microbial retention requirement, fluid or gas type, contamination level, and downstream cleanliness target. Available ratings cover fine filtration ranges including 0.1 μm, 0.22 μm, 0.45 μm, and larger pore sizes. Selection should balance retention performance, flow rate, and allowable pressure drop.
Can the Compact Disc Filter Cartridge be used for both liquid and gas filtration?
Yes. Different membrane materials allow the cartridge to be configured for either liquid or gas applications. Hydrophilic media are generally more suitable for aqueous liquids, while hydrophobic media such as PTFE can be selected for gas filtration. Final suitability should be confirmed according to fluid or gas composition, pressure, temperature, and membrane compatibility.
What operating limits should be considered for this disc filter cartridge?
The listed maximum operating temperature is 60°C. Maximum operating pressure varies between liquid and gas service and also changes with temperature. Actual allowable conditions depend on the selected membrane material, process medium, flow rate, and operating temperature, so the complete configuration should be confirmed before use.
Is the Compact Disc Filter Cartridge suitable for sterilization and high-purity applications?
The cartridge uses heat-sealing technology to avoid adhesive contamination and is designed with low extractables for clean processing. Certain configurations are suitable for sterilization-related and high-purity applications, but final suitability depends on membrane material, sterilization method, required biosafety level, and validated process conditions.